Home / Technologies / VOCs and solvents / Catalytic oxidation
DestroysVOCs and solvents
Oxidizes VOCs over a catalyst bed at a much lower temperature than thermal oxidation; the result is CO₂, water and heat. It is designed for low and medium flow rates and concentrations.

Operating temperature
250–450 °C
VOC efficiency
> 95 %
Flow rate
1,000–30,000 Nm³/h
VOC concentration
0.1–10 g/Nm³
Operating principle
A heat exchanger heats the incoming gas with the cleaned gas.
In the chamber with the catalyst bed, at 250–450 °C, the VOCs are converted into CO₂, water and heat.
The heat of the cleaned gas goes back to the process or is used externally.
Critical parameters are monitored continuously and the plant runs automatically.
Specifications
| Operating temperature | 250–450 °C |
| VOC removal efficiency | > 95 % |
| Air flow rate | 1,000–30,000 Nm³/h |
| VOC concentration | 0.1–10 g/Nm³ |
| Autothermal point | Around 2–3 g/Nm³ with a recuperative heat exchanger; lower with regenerative heat recovery |
| Heat exchanger thermal efficiency | 50–75% with a recuperative heat exchanger |
| Catalysts | Noble metals (Pt, Pd, Ag, Au) on a ceramic support; metal oxides (V, Cr, Mn, Fe, Co, Ni, Cu) for chlorinated compounds |
| Catalyst life | 4–5 years |
| Catalyst poisons | Phosphorus, arsenic, halogens, lead, sulfur, silicon |
| Execution | Pre-assembled in a 20 or 40 ft container; automatic operation |