Home / Technologies / VOCs and solvents / Catalytic oxidation

DestroysVOCs and solvents

Catalytic oxidation

Oxidizes VOCs over a catalyst bed at a much lower temperature than thermal oxidation; the result is CO₂, water and heat. It is designed for low and medium flow rates and concentrations.

Other technologies
Catalytic oxidation – plant diagram

Operating temperature

250–450 °C

VOC efficiency

> 95 %

Flow rate

1,000–30,000 Nm³/h

VOC concentration

0.1–10 g/Nm³

Operating principle

How it works

  1. 01

    Preheating

    A heat exchanger heats the incoming gas with the cleaned gas.

  2. 02

    Catalytic oxidation

    In the chamber with the catalyst bed, at 250–450 °C, the VOCs are converted into CO₂, water and heat.

  3. 03

    Heat recovery

    The heat of the cleaned gas goes back to the process or is used externally.

  4. 04

    Control

    Critical parameters are monitored continuously and the plant runs automatically.

Specifications

Technical data

Operating temperature250–450 °C
VOC removal efficiency> 95 %
Air flow rate1,000–30,000 Nm³/h
VOC concentration0.1–10 g/Nm³
Autothermal pointAround 2–3 g/Nm³ with a recuperative heat exchanger; lower with regenerative heat recovery
Heat exchanger thermal efficiency50–75% with a recuperative heat exchanger
CatalystsNoble metals (Pt, Pd, Ag, Au) on a ceramic support; metal oxides (V, Cr, Mn, Fe, Co, Ni, Cu) for chlorinated compounds
Catalyst life4–5 years
Catalyst poisonsPhosphorus, arsenic, halogens, lead, sulfur, silicon
ExecutionPre-assembled in a 20 or 40 ft container; automatic operation

Advantages

  • Lower energy use than thermal oxidation
  • Less NOx, because it runs at a lower temperature
  • Compact design, easy to fit into existing lines
  • No secondary waste
  • Energy recovery for external uses

Field of application

  • Low and medium flow rates
  • Stable, medium VOC loads
  • Gas streams free of catalyst poisons, or with pretreatment

Limitations

  • Poisons (P, As, halogens, Pb, S, Si) make gas pretreatment necessary
  • The catalyst is replaced every 4–5 years
  • Platinum catalysts lose activity in the presence of chlorine
  • High loads call for thermal oxidation

Industries

Where it is used

PharmaceuticalsFine chemicalsPrintingPlasticsPaints and varnishesWood industryFoodMetalworkingCosmetics

Datasheet

Full datasheet: Catalytic oxidation

Dimensions, design data and operating ranges. Leave us your details and an engineer will send you the datasheet and tell you whether this technology fits your plant.

All technologies

Datasheet

Request the full datasheet

Choose the technology and leave us your details. An engineer who knows that technology will send you the datasheet.

  • Full technical data for the technology you choose
  • An assessment of whether it suits your gas or your effluent

Would you rather write to us directly?

info@wizzum.com