Home / Technologies / Odors / Dry filter

AdsorbsOdors

Dry filter (adsorption and chemisorption)

The gas passes through a fixed bed of adsorbents, solid reagents or catalysts. The pollutants are retained by physical adsorption or by chemical reaction with the solid.

Other technologies
Dry filter (adsorption and chemisorption) – plant diagram

Efficiency

> 99% with the right adsorbent

Use

Small flow rates, low or moderate concentration

Saturation

Shown by a change of color

Flow rate

Up to around 5,000 m³/h

Operating principle

How it works

  1. 01

    Gas characterization

    The gas is analyzed: O₂, CO₂ and water vapor determine which adsorbent to choose.

  2. 02

    Passage through the bed

    The gas passes through one or more adsorbent beds with the necessary contact time.

  3. 03

    Retention

    The pollutants are adsorbed or react with the solid.

  4. 04

    Replacement

    The inorganic adsorbent changes color when saturated, which can be seen through a sight glass.

Specifications

Technical data

Activated carbonAdsorption of many volatile organic compounds
Impregnated carbonBottom layer in layered beds
Inorganic adsorbentsFor acid and alkaline gases and halogens; non-flammable; they change color when saturated
Layered bedImpregnated carbon at the bottom and two layers of inorganic adsorbent on top, for mixed streams
PollutantsNH₃, amines, H₂S, mercaptans, NO, NO₂, SO₂, Cl₂, HCl, HBr, F₂, HF, SiCl₄, solvents, odors
Efficiency> 99% with the right adsorbent and enough contact time
InstrumentationSight glass at the top of the bed, pressure transmitter and/or rupture disc, overheating protection
Gas compositionSome adsorbents need O₂ and others become saturated with CO₂; some require water vapor and others lose activity with it
Flow rateUp to around 5,000 m³/h

Advantages

  • Compact design
  • Efficiency > 99% with the right adsorbent
  • Non-flammable inorganic adsorbents
  • Saturation is shown by a change of color

Field of application

  • Small flow rates at low or moderate concentration
  • Odor reduction and polishing after a scrubber
  • Mixed streams, with layered beds

Limitations

  • The cost of the adsorbent limits it to small flow rates
  • Risk of overheating with large mass loads
  • Pressure drop increases as it saturates
  • Depends heavily on the gas composition

Industries

Where it is used

Wastewater treatment plants and pumping stationsChemicalsEthylene oxide sterilizationStorage terminals

Datasheet

Full datasheet: Dry filter

Dimensions, design data and operating ranges. Leave us your details and an engineer will send you the datasheet and tell you whether this technology fits your plant.

All technologies

Datasheet

Request the full datasheet

Choose the technology and leave us your details. An engineer who knows that technology will send you the datasheet.

  • Full technical data for the technology you choose
  • An assessment of whether it suits your gas or your effluent

Would you rather write to us directly?

info@wizzum.com

The first conversation is free and with no obligation.