Home / Technologies / Water and discharge / Physico-chemical treatment

SeparatesWater and discharge

Physico-chemical treatment

It combines flotation, sedimentation, precipitation, coagulation and flocculation, neutralization, adsorption, filtration, electrocoagulation and advanced oxidation to separate or transform the pollutants in wastewater.

Other technologies
Physico-chemical treatment – plant diagram

Configurations

Compact, continuous or batch

Pollutants

Suspended solids, oils, metals, color, toxic substances

Energy consumption

0.05–0.15 kWh/m³

Flow rate

Modular; sized for the peak flow rate and retention time

Operating principle

How it works

  1. 01

    Neutralization

    pH adjustment, often together with precipitation.

  2. 02

    Coagulation and flocculation

    The coagulant destabilizes the colloids (0.001–1 mm) and the flocculant binds them into flocs.

  3. 03

    Separation

    Dissolved air flotation (DAF) for oils and fats, or sedimentation for precipitated solids.

  4. 04

    Polishing

    Filtration, adsorption or advanced oxidation, depending on the pollutant that remains.

Specifications

Technical data

Flotation (DAF)Oils, fats and suspended solids lighter than water
SedimentationSuspended solids after precipitation or coagulation
PrecipitationHexavalent chromium, heavy metals, cyanides
Coagulation and flocculationColloids from 0.001 to 1 mm
AdsorptionActivated carbon or zeolites, thermally regenerated; color, organochlorine compounds, metals
FiltrationGravity (gravel, sand, carbon) or pressure (filter press)
ElectrocoagulationLow-voltage direct current with soluble aluminum or iron electrodes
Advanced oxidationOzone, hydrogen peroxide, hypochlorite, Fenton's reagent or UV, separately or combined
ConfigurationsCompact batch treatment plant, continuous or batch installation
Flow rateModular; sized for the peak flow rate and retention time
Typical dosesFerric chloride 50–200 mg/l (coagulants in general, 50–300 mg/l); polyelectrolyte 1–5 mg/l
Rapid mixing (coagulation)Velocity gradient of 800–1,200 s⁻¹ for 30–60 s
Slow mixing (flocculation)20–80 s⁻¹ for 15–30 min
Settling velocity0.5–1 m/h in a static clarifier; up to 3 m/h in a lamella clarifier
Sludge quantity1–2% of the treated volume as wet sludge, around 3–6 kg/m³
Energy consumption0.05–0.15 kWh/m³ for coagulation and flocculation
Metal precipitationEach metal has its optimum pH (zinc, 9–10); lime or caustic soda is dosed with inline measurement
Hexavalent chromiumFirst reduced to Cr(III) at pH 2–3 and a redox potential of around +250 mV with ferrous sulfate or metabisulfite; then the pH is raised to 8–9 and it is precipitated
CyanidesFirst oxidized to cyanates with hypochlorite at pH 10–11 and redox of 600–650 mV; around 2.7 mg of chlorine per mg of cyanide, plus 25% excess
EqualizationTank for at least 4–6 h of inlet flow
Indicative footprint3–6 m² per m³/h (coagulation and sedimentation)
Preliminary testJar test with the actual wastewater to choose the reagents and doses

Advantages

  • Custom design based on the wastewater characteristics
  • A wide range of stages for very different pollutants
  • Electrocoagulation with a very low treatment cost

Field of application

  • Suspended solids, oils and fats
  • Heavy metals, chromium VI, cyanides, pesticides
  • Color, refractory organic compounds, brines

Limitations

  • Consumes reagents and produces sludge, around 3–6 kg per m³
  • Removes dissolved organic compounds poorly: a biological stage is usually needed
  • Complexing agents in some baths make metal precipitation harder

Industries

Where it is used

ChemicalsPharmaceuticalsCosmeticsTextilesSlaughterhousesDairiesFruit and vegetable processingWineriesPicklesMetalworkingPlasticsTanning

Datasheet

Full datasheet: Physico-chemical treatment

Dimensions, design data and operating ranges. Leave us your details and an engineer will send you the datasheet and tell you whether this technology fits your plant.

All technologies

Datasheet

Request the full datasheet

Choose the technology and leave us your details. An engineer who knows that technology will send you the datasheet.

  • Full technical data for the technology you choose
  • An assessment of whether it suits your gas or your effluent

Would you rather write to us directly?

info@wizzum.com