Home / Technologies / Water and discharge / Physico-chemical treatment
SeparatesWater and discharge
It combines flotation, sedimentation, precipitation, coagulation and flocculation, neutralization, adsorption, filtration, electrocoagulation and advanced oxidation to separate or transform the pollutants in wastewater.

Configurations
Compact, continuous or batch
Pollutants
Suspended solids, oils, metals, color, toxic substances
Energy consumption
0.05–0.15 kWh/m³
Flow rate
Modular; sized for the peak flow rate and retention time
Operating principle
pH adjustment, often together with precipitation.
The coagulant destabilizes the colloids (0.001–1 mm) and the flocculant binds them into flocs.
Dissolved air flotation (DAF) for oils and fats, or sedimentation for precipitated solids.
Filtration, adsorption or advanced oxidation, depending on the pollutant that remains.
Specifications
| Flotation (DAF) | Oils, fats and suspended solids lighter than water |
| Sedimentation | Suspended solids after precipitation or coagulation |
| Precipitation | Hexavalent chromium, heavy metals, cyanides |
| Coagulation and flocculation | Colloids from 0.001 to 1 mm |
| Adsorption | Activated carbon or zeolites, thermally regenerated; color, organochlorine compounds, metals |
| Filtration | Gravity (gravel, sand, carbon) or pressure (filter press) |
| Electrocoagulation | Low-voltage direct current with soluble aluminum or iron electrodes |
| Advanced oxidation | Ozone, hydrogen peroxide, hypochlorite, Fenton's reagent or UV, separately or combined |
| Configurations | Compact batch treatment plant, continuous or batch installation |
| Flow rate | Modular; sized for the peak flow rate and retention time |
| Typical doses | Ferric chloride 50–200 mg/l (coagulants in general, 50–300 mg/l); polyelectrolyte 1–5 mg/l |
| Rapid mixing (coagulation) | Velocity gradient of 800–1,200 s⁻¹ for 30–60 s |
| Slow mixing (flocculation) | 20–80 s⁻¹ for 15–30 min |
| Settling velocity | 0.5–1 m/h in a static clarifier; up to 3 m/h in a lamella clarifier |
| Sludge quantity | 1–2% of the treated volume as wet sludge, around 3–6 kg/m³ |
| Energy consumption | 0.05–0.15 kWh/m³ for coagulation and flocculation |
| Metal precipitation | Each metal has its optimum pH (zinc, 9–10); lime or caustic soda is dosed with inline measurement |
| Hexavalent chromium | First reduced to Cr(III) at pH 2–3 and a redox potential of around +250 mV with ferrous sulfate or metabisulfite; then the pH is raised to 8–9 and it is precipitated |
| Cyanides | First oxidized to cyanates with hypochlorite at pH 10–11 and redox of 600–650 mV; around 2.7 mg of chlorine per mg of cyanide, plus 25% excess |
| Equalization | Tank for at least 4–6 h of inlet flow |
| Indicative footprint | 3–6 m² per m³/h (coagulation and sedimentation) |
| Preliminary test | Jar test with the actual wastewater to choose the reagents and doses |