2019Valencia region, SpainCeramic tilesAcid gases
A maker of ceramic floor and wall tiles in the Valencia region had to clean the acid gases from its firing kiln, which leave at around 200 °C. To treat them in a wet scrubber they first had to be cooled, so a Venturi was installed ahead of the absorption tower.
30,000 m³/h
of kiln gases, design flow
01
The gas leaves the kiln at about 200 °C carrying acid compounds that must be absorbed and neutralised before the stack. A packed polypropylene tower cannot take that temperature: the gas had to reach it below 70 °C and without the particles it brings from the kiln.
30,000 m³/h
design flow
200 °C
at the Venturi inlet
< 70 °C
at the tower inlet
02
Two stages in series: a cooling Venturi followed by an alkaline scrubbing tower with caustic soda in counter-current. A centrifugal fan with a frequency drive moves the whole flow, and dosing, water make-up and bleed run on their own.
STEP 1
30,000 m³/h at about 200 °C, with acid compounds and particles.
STEP 2
Stainless steel lined with copolymer. Sprayed water cools the gas and captures particles, which collect at the bottom of the tank.
STEP 3
Polypropylene, Ø 2.8 × 8 m. NaOH solution runs down the packing (140 m²/m³) against the gas, which rises at 1.8 m/s.
STEP 4
90 kW centrifugal fan with frequency drive, 600 mm w.g. Automatic dosing, water make-up and bleed.
03
Design data of the installation.
Flow
30,000 m³/h
Tower inlet temperature
< 70 °C
Scrubbing tower
PP, Ø 2.8 × 8 m
Both stages run in series and in automatic mode. The Venturi sends cool, less dusty gas to the tower, and the caustic soda neutralises the acids in the packing. Acid gas emissions are below the legal limit.
< 70 °C
at the tower inlet
1.8 m/s
gas velocity in the tower
90 kW
fan with frequency drive
05
2019 · Spain · Pharmaceuticals (API)
RTO · quench · scrubber
99,9 %
VOC destruction
≤ 20
mg/m³ of VOCs at the stack
Off-gases with methylene chloride treated safely in continuous operation.
Read the case study →
06
2017 · Urban area · Plastic packaging
Zeolite concentrators · RTO · steam boiler
230 000
Nm³/h
≈ 10 000 €
in savings per month
Surplus heat from the RTO produces 1 t/h of steam for the plant.
Read the case study →
08
2019 · Spain · Vegetable oil
Venturi bioscrubber · bag filter · ATEX
18 000
m³/h
ATEX
design and certification
VOCs and dust below the limits, continuous operation with minimal maintenance.
Read the case study →