2021Madrid, SpainLandfillBiogas
An active landfill near Madrid uses the biogas from its waste to run a combined heat and power (CHP) engine. Inside the engine, the siloxanes in the gas turn into silica that wears down engine parts, so they had to be removed before combustion.
Reference case by DESOTEC, manufacturer of the filter.
1,200 Nm³/h
of biogas with no detectable siloxanes at the outlet
01
The biogas carried three kinds of contaminants: 15 to 30 mg/m³ of siloxanes, around 300 mg/m³ of VOCs and 100 to 225 mg/m³ of hydrogen sulphide (H₂S). Siloxanes were the priority, because when they burn they form silica, a kind of sand that wears the engine. H₂S damages it too. And, as at any landfill, the gas composition changes a lot from one day to the next.
15–30 mg/m³
of siloxanes
≈ 300 mg/m³
of VOCs
100–225 mg/m³
of H₂S
02
A mobile activated carbon filter (AIRCON HC-XL) loaded with a standard VOC carbon and sized for a high biogas flow. The manufacturer collects the spent carbon and reactivates it for reuse.
STEP 1
1,200 Nm³/h containing siloxanes, VOCs and H₂S.
STEP 2
Mobile unit delivered two weeks after the order and connected by the client.
STEP 3
Receives gas with no detectable siloxanes.
STEP 4
Spent carbon travels in the same closed unit, is analysed, desorbed and reactivated.
03
Values at the filter outlet.
Siloxanes
Not detectable
Treated flow
1,200 Nm³/h
Expected carbon change
≈ 8 months
Since start-up in June 2021, no siloxanes have been detected in the gas going into the engine, and the installation needs very little maintenance. With clean gas, the engine is expected to stop less often and last longer. Because the biogas varies so much, the client monitors concentrations, and a second filter in series is being considered so the carbon can be changed without leaving the engine unprotected.
0
detectable siloxanes at the outlet
≈ 8 months
between carbon changes
2 weeks
from order to delivery
05
2019 · Spain · Pharmaceuticals (API)
RTO · quench · scrubber
99,9 %
VOC destruction
≤ 20
mg/m³ of VOCs at the stack
Off-gases with methylene chloride treated safely in continuous operation.
Read the case study →
06
2017 · Urban area · Plastic packaging
Zeolite concentrators · RTO · steam boiler
230 000
Nm³/h
≈ 10 000 €
in savings per month
Surplus heat from the RTO produces 1 t/h of steam for the plant.
Read the case study →
08
2019 · Spain · Vegetable oil
Venturi bioscrubber · bag filter · ATEX
18 000
m³/h
ATEX
design and certification
VOCs and dust below the limits, continuous operation with minimal maintenance.
Read the case study →