Home / Technologies / Water and discharge / MBR bioreactor
TreatsWater and discharge
Biological treatment with activated sludge in which the final separation is done by submerged membranes instead of a clarifier. The water comes out filtered, free of suspended solids and with high bacteria retention, ready to discharge or reuse.

Capacity
15–1,000 m³/day
Population equivalent
300–32 000
Biomass in the reactor
6,000–12,000 mg/l
Footprint
Up to 70% smaller
Operating principle
A screen removes coarse solids and fibers to protect the membranes.
A tank with no aeration and controlled mixing, where denitrification takes place.
The aerated activated sludge breaks down organic matter and removes nutrients.
The submerged flat-sheet membranes separate the biomass and suspended solids from the treated water (permeate).
UV radiation or chemical dosing, if the water's use requires it.
The sludge returns to the anoxic zone and only a small excess is purged from time to time.
Specifications
| Capacity | 15–1,000 m³/day in a compact unit; up to 18,000 m³/day with separate membrane filtration connected to the reactor |
| Population equivalent | 300–32 000 |
| Membranes | Flat sheet, submerged, PFAS-free CPVC polymer (no fluorine or C–F bonds) |
| Biomass concentration | 6,000–12,000 mg/l, higher than in a reactor with a conventional clarifier |
| Reactor | Anoxic tank, aerobic reactor, air diffusers, membrane modules and internal recirculation |
| Equipment room | Reactor and membrane blowers, permeate and dosing pumps, permeate and recirculation flow meters, pressure sensor |
| Connections | Gravity wastewater inlet, mains water inlet, permeate outlet, sludge purge, inlet for cleaning products and antifoam, drain |
| CIP cleaning | Without removing the membranes: acid (citric acid or, in specific cases, hydrochloric) for salts and carbonates, and sodium hypochlorite for biofilm |
| Control | PLC with automatic control of pumps, recirculation, permeate, pressures and cleaning cycles; remote monitoring |
| Supply | Factory-assembled and tested; minimal civil works |
| Effluent quality | COD < 40 mg/l (inlet < 600; 93%); BOD < 10 mg/l (inlet < 300; 97%); TSS < 2 mg/l (inlet < 300; 99%); TKN < 10 mg/l (inlet < 40; 75%); oils and fats < 1 mg/l (inlet < 50; 98%) |
| Microbiological retention | E. coli, nematodes and Legionella 90–100%; viruses 60–90% |
| Design parameters | Volumetric loading 1.2–3.2 kg COD/m³·d; retention time 4–6 h; sludge age 5–20 days |
| Power consumption | 0.8–1.5 kWh per m³ of treated water (blowers and pumps) |
| Membrane life | 5–7 years, depending on fouling and cleaning cycles |
| Indicative footprint | 3–6 m² per m³/h of flow |
| Civil works versus equipment | Roughly 50% / 50% |
| Capacity (m³/day) | Units | Volume (m³) | Filtration area (m²) | Footprint (m²) | Dimensions L × W × H (m) | Consumption (kWh) |
|---|---|---|---|---|---|---|
| 50 | 1 | 22 | 80 | 19 | 8 × 2.2 × 2.2 | 4 |
| 100 | 1 | 37 | 160 | 29 | 12 × 2.2 × 2.2 | 8 |
| 150 | 1 | 37 | 240 | 29 | 12 × 4.4 × 2.2 | 12 |
| 200 | 1 | 75 | 500 | 40 | 12 × 3 × 3 | 26 |
| 300 | 1 | 75 | 500 | 40 | 12 × 3 × 3 | 26 |
| 400 | 2 | 112 | 660 | 69 | 12 × 5.2 × 3 | 34 |
| 500 | 1 | 111 | 900 | 48 | 12 × 3.6 × 3.6 | 46 |
| 600 | 2 | 150 | 1000 | 79 | 12 × 6 × 3 | 52 |
| 800 | 2 | 186 | 1400 | 87 | 12 × 6.6 × 3.6 | 72 |
| 1000 | 2 | 222 | 1800 | 95 | 12 × 7.2 × 3.6 | 92 |
Industries
Datasheet
Dimensions, design data and operating ranges. Leave us your details and an engineer will send you the datasheet and tell you whether this technology fits your plant.
Datasheet
Choose the technology and leave us your details. An engineer who knows that technology will send you the datasheet.
Would you rather write to us directly?
info@wizzum.com