Thermal vacuum crystallizer with forced circulation

An evaporator-crystallizer for large volumes, powered by saturated steam or hot water. It handles a high pollutant load and salt precipitation; fast circulation and the inclined heat exchanger prevent scaling and make draining easier.

The full range
Thermal vacuum crystallizer with forced circulation – plant diagram

Capacity

20,000–100,000 l/day

Thermal power

630–3,140 kWth

Evaporation temperature

Around 60 °C

Vacuum

Around 200 mbar

Operating principle

How it works

  1. 01

    Heating

    Steam or hot water heats the product in a shell and tube heat exchanger.

  2. 02

    Forced circulation

    The recirculation pump runs at high speed so that no scale forms.

  3. 03

    Crystallization

    The dissolved salts precipitate in the vertical conical chamber.

  4. 04

    Condensation and discharge

    The vapor condenses with cooling water; the inclined heat exchanger drains into the chamber during shutdowns.

Specifications

Technical data

TechnologyEvaporation with thermal energy, forced circulation, single effect
Heat sourceSaturated steam or hot water
CondensationCooling water
ChamberVertical, conical
Heat exchangerShell and tube, inclined for draining
Mist eliminatorMesh demister
Vacuum systemLiquid ring pump
Standard materialAISI 316 / 316L
Corrosion-resistant materialSuper duplex 2507
Protection rating · power supplyIP54 · 400 V III + PE 50 Hz

Available sizes

Capacity (l/day)20 00040 00060 00080 000100 000
Electrical power (kW)2632354648
Thermal power (kWth)6301260188525153140
Length (cm)650700700750810
Width (cm)260360400400400
Height (cm)510600660660739,5

The thermal condensation capacity equals the evaporation capacity. Indicative values for clean water at 20 °C and 1013 mbar in steady-state operation. Actual values depend on the wastewater composition and the required final concentration.

Advantages

  • Large volumes with a high pollutant load
  • No scaling thanks to fast circulation
  • Uses the steam or hot water available
  • 24 h automatic operation

Applications

  • Large brine volumes
  • Final stage of zero liquid discharge systems

Datasheet

Full datasheet: Thermal · forced circulation

Dimensions, design data and operating ranges. Leave us your details and an engineer will send you the datasheet and tell you whether this technology fits your plant.

All technologies

Environmental engineering for industry.
Industrial wastewater, emissions and odors.

OFFICE

Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com

© 2026 Wizzum. All rights reserved.

Datasheet

Request the full datasheet

Choose the technology and leave us your details. An engineer who knows that technology will send you the datasheet.

  • Full technical data for the technology you choose
  • An assessment of whether it suits your gas or your effluent

Would you rather write to us directly?

info@wizzum.com

The first conversation is free and with no obligation.