Home / Technologies / Water and discharge / Crystallization and ZLD

Zero dischargeWater and discharge

Vacuum crystallization and Zero Liquid Discharge (ZLD)

Evaporator-crystallizers for concentrated brine: they raise the concentration above the solubility limit so the dissolved salts precipitate as crystals and the plant no longer needs to discharge liquid.

Other technologies
Vacuum crystallization and Zero Liquid Discharge (ZLD) – plant diagram

Capacity

250–100,000 l/day

Water recovery

Up to 99%

Waste reduction

Up to 90%

Power consumption

64–270 kWh/m³

Operating principle

How it works

  1. 01

    Food

    The brine or wastewater comes in already concentrated in previous stages.

  2. 02

    Vacuum concentration

    The water evaporates at reduced pressure until the salt concentration exceeds the solubility limit.

  3. 03

    Crystallization

    The salts precipitate; a scraper or fast circulation prevents scaling.

  4. 04

    Discharge

    The solid or semi-solid residue is discharged, with a screw conveyor if required; the distillate is reused.

Range

The crystallizer range

Six vacuum crystallization technologies that take brine down to solid or semi-solid salt. They are chosen according to the energy available, the capacity and the final form of the residue.

Specifications

Technical data

Energy sourcesElectric (heat pump (HP) or mechanical vapor recompression (MVR)) or thermal (saturated steam or hot water)
Power consumption220–250 kWh/m³ (heat pump (HP) with scraper) · 270 kWh/m³ (heat pump (HP), drying) · 64 kWh/m³ (mechanical recompression)
Installed power (heat pump (HP) with scraper)6.5–35 kW for 500–3,000 l/day
CondensationThermal units with cooling water of the same capacity as the evaporation
Operating vacuumAround 60 mbar (heat pump) · around 200 mbar (thermal) · around 700 mbar (recompression)
Scaling preventionMotorized internal scraper or high-speed recirculation pump
Residue dischargeBy screw or centrifugal pump, by gravity or by overpressure; optional screw conveyor in the horizontal chamber
AutomationFoam control with antifoam dosing; automatic internal washing; optional remote monitoring
OptionsDistillate separator to separate solvents; PTFE non-stick lining; super duplex or titanium scraper
WastewaterVery high-salinity brines, scaling water, non-volatile organic compounds
ProductsDistilled water for reuse and crystals of salts, metals or other solids
MaterialsAISI 316 / 316L; super duplex 2507, titanium or other corrosion-resistant alloys
Data basisClean water distillate at 20 °C and 1013 mbar
Types of thermal crystallizersMagma circulation (Oslo type), forced circulation with flash evaporation, and jacketed heat exchanger with scraper
Cooling crystallizationFor salts whose solubility drops with temperature, such as sodium sulfate
Selective crystallizationControlling temperature and concentration separates one salt at a time (for example, sodium sulfate first and then sodium chloride)
Solid-liquid separationBasket, peeler or pusher centrifuges, which give crystals with 90–97% dry matter; Nutsche filters for pharmaceutical-grade salts
Salt dryingRotary or fluidized-bed dryers, down to moisture below 5%
Indicative footprint4–7 m² per m³/h; indoor installation

Crystallizer range comparison

TechnologyEnergyCapacityConsumptionTemperature · vacuumApplication
Heat pump (HP) · internal scraperElectric250–4,000 l/day220–250 kWh/m³Around 35 °C · around 60 mbarScaling water; high concentration and crystallization
Heat pump (HP) · horizontal chamber (drying)Electric250–1,000 l/day270 kWh/m³Around 35 °C · around 60 mbarSolid or semi-solid residue; recovery of metals and salts
Mechanical recompression (MVR) · forced circulationElectric + support steam600–2,500 l/h64 kWh/m³ + 36–226 kWthAround 90 °C · around 700 mbarHigh pollutant load and salt precipitation
Thermal · internal scraperSteam or hot water2,000–20,000 l/day4.2–5 kW + 65–630 kWthAround 60 °C · around 200 mbarScaling water
Thermal · horizontal chamber (drying)Steam or hot water500–3,000 l/day2.7–7.4 kW + 16–94 kWthAround 60 °C · around 200 mbarSolid or semi-solid residue
Thermal · forced circulationSteam or hot water20,000–100,000 l/day26–48 kW + 630–3,140 kWthAround 60 °C · around 200 mbarLarge volumes with a high load and salt precipitation

Advantages

  • Minimal final residue, with less transport and fewer external services
  • Good-quality recovered water for reuse
  • Recovery of salts, metals and other raw materials
  • Less storage at the plant
  • Makes it easier to meet discharge limits

Field of application

  • Plants without an authorized discharge point
  • Brines and reverse osmosis reject
  • Adhesives and heavily scaling liquids
  • Developing and fixing water, press washing and paint recovery
  • High costs for external waste removal

Limitations

  • Mechanical recompression units need support steam
  • Thermal units need cooling water
  • Reference capacities for clean water

Industries

Where it is used

EnergyAutomotiveFoodMetal treatment and electroplatingChemicals and pharmaceuticalsWaste and battery recyclingBuilding materialsBiogas

Datasheet

Full datasheet: Crystallization and ZLD

Dimensions, design data and operating ranges. Leave us your details and an engineer will send you the datasheet and tell you whether this technology fits your plant.

All technologies

Datasheet

Request the full datasheet

Choose the technology and leave us your details. An engineer who knows that technology will send you the datasheet.

  • Full technical data for the technology you choose
  • An assessment of whether it suits your gas or your effluent

Would you rather write to us directly?

info@wizzum.com

The first conversation is free and with no obligation.