2006 and 2016Murieta, NavarreMetalZLD
At the Schmidt + Clemens plant in Murieta (Navarre), metal parts are inspected with non-destructive penetrant testing. The wash water could not be discharged: it had to be recycled, leaving as little waste as possible to manage.
Reference case by Condorchem Envitech, manufacturer of the technology.
Zero discharge
of wash water from testing
01
Penetrant testing leaves wash water that the plant had to treat without discharging anything. The first installation, built in 2006, treated about 4 m³ of this water. In 2016 production grew and the volume rose to 15 m³ a day, so a larger plant was needed with the same aim: reuse the water and reduce the final waste.
4 m³
of wash water in 2006
15 m³/day
since the 2016 expansion
Zero discharge
as the target
02
A complete vacuum evaporation plant followed by simple distillation, which concentrates the waste further. In 2016 it was replaced by a larger plant with the same layout.
STEP 1
From penetrant testing.
STEP 2
ENVIDEST LT VS 4500 in 2006; ENVIDEST LT VS 15000 since 2016.
STEP 3
AV-110, replaced by an AV-160 in the expansion. Concentrates the waste.
STEP 4
Goes back to washing the parts.
STEP 5
A minimal volume of waste is left to manage.
03
Installation result.
Wash water discharge
Zero
Capacity since 2016
15 m³/day
First plant
2006
The plant runs with zero discharge: water is recycled in the washing process itself and only a small concentrate is left to manage. When production increased, the installation was replaced by a larger one without changing the treatment layout.
Zero discharge
of wash water
15 m³/day
capacity after the expansion
Recycled water
for washing the parts
03
2009 · Valencia, Spain · Food industry
Vacuum evaporator · spray drying
TDS < 100
ppm in the distillate
55,000 l
per day
Evaporator heated with waste heat from cogeneration.
Read the case study →
04
2008 · Murcia, Spain · Chemicals and cosmetics
MVR evaporator · crystallizer
7 000 → 50
µS/cm conductivity
3 000 → 5
mg/l of chlorides
Zero liquid discharge. An award-winning project for its environmental benefit.
Read the case study →
02
2020 · Mexico · Detergents and hygiene
MBR · activated carbon · filter press
235 m³
per day
pH 0–11
at the inlet
Meets the limits with a margin, and the water can be reused.
Read the case study →
Process water you cannot discharge?
We study whether vacuum evaporation lets you recycle the water and reduce waste before you ask for quotes.
OFFICE
Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com
© 2026 Wizzum. All rights reserved.
