2008Murcia, SpainChemicals and cosmeticsZLD
The new municipal bylaw required a discharge conductivity below 3,000 µS/cm. A chemical and cosmetics plant in the Region of Murcia was discharging water with more than 7,000 µS/cm, in an area short of water.
7,000 → 50 µS/cm
conductivity before and after
01
The saline wastewater had a conductivity above 7,000 µS/cm and a lot of chloride, sulfate and suspended solids, and the new limit was 3,000 µS/cm. With water scarce in the area, recovering it was a strategic matter.
> 7,000 µS/cm
wastewater conductivity
3,000 µS/cm
new municipal limit
66 m³/day
of wastewater to treat
02
A ZLD system for 66 m³/day: an evaporator with mechanical vapor recompression and a crystallizer, built in corrosion-resistant steels.
STEP 1
Suspended solids are removed before evaporation.
STEP 2
Mechanical vapor recompression concentrates the wastewater up to 14 times.
STEP 3
Conductivity of 20–50 µS/cm: the water goes back to the plant or is discharged.
STEP 4
Operates at elevated temperature and produces solid salts and a small amount of wet sludge.
STEP 5
Special stainless steel alloys with high corrosion resistance.
03
Values at the plant outlet.
Conductivity
> 7,000 → < 50 µS/cm
Chlorides
3,000 → < 5 mg/l
Concentration
up to 14 times
Discharge
zero
The plant fully complies with local regulations. The recovered water can be reused, which cuts fresh water consumption, and the discharge is gone. The plant is cost-effective, has low operating costs and has received several environmental awards.
< 50 µS/cm
conductivity of the recovered water
< 5 mg/l
chlorides
0
of wastewater discharged
03
2009 · Valencia, Spain · Food industry
Vacuum evaporator · spray drying
TDS < 100
ppm in the distillate
55,000 l
per day
Evaporator heated with waste heat from cogeneration.
Read the case study →
02
2020 · Mexico · Detergents and hygiene
MBR · activated carbon · filter press
235 m³
per day
pH 0–11
at the inlet
Meets the limits with a margin, and the water can be reused.
Read the case study →
01
2021 · Portugal · PPE manufacturing
DAF · MBR · ultrafiltration
> 30 000
mg/l of COD at the inlet
20 m³
per day
Discharge limits met, water suitable for irrigation.
Read the case study →
Saline wastewater above the conductivity limit?
We work out whether an MVR evaporator with a crystallizer pays off at your plant and how much water you would recover.
OFFICE
Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com
© 2026 Wizzum. All rights reserved.