Home / Projects / ZLD

2008Murcia, SpainChemicals and cosmeticsZLD

ZLD for saline wastewater in the chemical industry: MVR evaporator and crystallizer.

The new municipal bylaw required a discharge conductivity below 3,000 µS/cm. A chemical and cosmetics plant in the Region of Murcia was discharging water with more than 7,000 µS/cm, in an area short of water.

7,000 → 50 µS/cm

conductivity before and after

01

The challenge

The saline wastewater had a conductivity above 7,000 µS/cm and a lot of chloride, sulfate and suspended solids, and the new limit was 3,000 µS/cm. With water scarce in the area, recovering it was a strategic matter.

> 7,000 µS/cm

wastewater conductivity

3,000 µS/cm

new municipal limit

66 m³/day

of wastewater to treat

02

The solution

A ZLD system for 66 m³/day: an evaporator with mechanical vapor recompression and a crystallizer, built in corrosion-resistant steels.

STEP 1

Neutralization and filtration

Suspended solids are removed before evaporation.

STEP 2

MVR evaporator

Mechanical vapor recompression concentrates the wastewater up to 14 times.

STEP 3

Distillate

Conductivity of 20–50 µS/cm: the water goes back to the plant or is discharged.

STEP 4

Crystallizer

Operates at elevated temperature and produces solid salts and a small amount of wet sludge.

STEP 5

Materials

Special stainless steel alloys with high corrosion resistance.

03

Results

Values at the plant outlet.

Conductivity

> 7,000 → < 50 µS/cm

Chlorides

3,000 → < 5 mg/l

Concentration

up to 14 times

Discharge

zero

The plant fully complies with local regulations. The recovered water can be reused, which cuts fresh water consumption, and the discharge is gone. The plant is cost-effective, has low operating costs and has received several environmental awards.

< 50 µS/cm

conductivity of the recovered water

< 5 mg/l

chlorides

0

of wastewater discharged

Saline wastewater above the conductivity limit?

We work out whether an MVR evaporator with a crystallizer pays off at your plant and how much water you would recover.

Environmental engineering for industry.
Industrial wastewater, emissions and odors.

OFFICE

Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com