2007 and 2008León and AsturiasEnergyZLD
Gas Natural Fenosa needed to treat the wastewater from flue gas desulphurisation (FGD) at two coal-fired power plants: La Robla (León), next to the Bernesga river, and Narcea (Tineo, Asturias), next to the Narcea river.
Reference case by Condorchem Envitech, manufacturer of the technology.
94%
of treated water returns to the process
01
Flue gas desulphurisation produces an effluent that each plant had to treat: 4 m³/h at La Robla and 5.5 m³/h at Narcea. La Robla has two thermal units, of 284.2 and 370.7 MW, and Narcea three, of 55.5, 166.6 and 364.1 MW. The aim was to discharge nothing and leave only salts as waste.
4 m³/h
of effluent at La Robla
5.5 m³/h
of effluent at Narcea
2 plants
coal-fired
02
At each plant, a complete installation with filtration pretreatment, a physico-chemical stage and a vacuum evaporator-crystalliser built from a special anti-corrosion material.
STEP 1
4 m³/h at La Robla and 5.5 m³/h at Narcea.
STEP 2
Effluent pretreatment.
STEP 3
Stage before evaporation.
STEP 4
ENVIDEST MFE-96.000 at La Robla and MFE-132.000 at Narcea, in anti-corrosion material.
STEP 5
94% of the water returns to the process; salts leave as solid waste.
03
Results at both plants.
Effluent discharge
Zero (ZLD)
Water recovered to the process
94%
Final waste
Salts
Both plants run with no liquid discharge. 94% of the treated water goes back into the plant process, and all that remains are salts, managed as waste in the smallest possible volume.
94%
water recovered
ZLD
no liquid discharge
2 plants
running since 2007 and 2008
04
2008 · Murcia, Spain · Chemicals and cosmetics
MVR evaporator · crystallizer
7 000 → 50
µS/cm conductivity
3 000 → 5
mg/l of chlorides
Zero liquid discharge. An award-winning project for its environmental benefit.
Read the case study →
03
2009 · Valencia, Spain · Food industry
Vacuum evaporator · spray drying
TDS < 100
ppm in the distillate
55,000 l
per day
Evaporator heated with waste heat from cogeneration.
Read the case study →
02
2020 · Mexico · Detergents and hygiene
MBR · activated carbon · filter press
235 m³
per day
pH 0–11
at the inlet
Meets the limits with a margin, and the water can be reused.
Read the case study →
Saline effluents you cannot discharge?
We assess whether a zero liquid discharge system with evaporation fits your plant before you commit the budget.
OFFICE
Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com
© 2026 Wizzum. All rights reserved.