Cyanide, hexavalent chromium and metals are not treated in the same way. How to separate the streams from a plating line and in what order to treat them.
CONTENTS
IN SHORT
When a discharge analysis comes back bad at an electroplating shop, the first reaction is to look at the treatment plant: more reagent, a different flocculant, a filter at the end. The fault is hardly ever there. It is a few metres upstream, in the sump where waters that should never have met are combined.
A copper, nickel, zinc or chromium line does not produce “a wastewater”. It produces four or five, each with its own chemistry, and some are incompatible with each other. Treating them as one is expensive in reagents and sludge, and sometimes in fines as well.
Water is used in degreasing, pickling and activation, in the rinses that follow each bath, in passivation and in the final wash. The rinses give the largest volume: lightly loaded water, but very variable from one hour to the next. Bath changes, equipment cleaning and floor washing give the opposite, low volume and high concentration, and they arrive all at once.
What the water carries depends on the line more than on the flow:
| Pollutant | Where it comes from | Why it complicates treatment |
|---|---|---|
| Metals (Cu, Ni, Zn, Cr) | Bath drag-out and rinses | Dissolved or as fines; each metal precipitates best at a different pH |
| Hexavalent chromium | Chromium plating and some passivation baths | It does not precipitate as a hydroxide; it has to be reduced to trivalent chromium first |
| Cyanide | Cyanide baths | Toxic, and it forms complexes with metals that prevent them from precipitating |
| Acids and alkalis | Pickling, degreasing, neutralisation | They shift the pH and attack tanks, pipes and pumps |
| Oils and surfactants | Degreasing | They coat the flocs and spoil settling |
| Complexing agents | Chelating agents in the baths, electroless nickel | They keep the metal in solution even when the pH is right |
| Suspended solids | Metal fines, bath sludge | They overload settling and the filters |
Mixing has specific consequences. If cyanide water meets acidic water, hydrogen cyanide, a lethal gas, is released inside the building. If chromium arrives together with other metals, each gets in the way of the others’ precipitation. If degreasing oil gets in, the sludge stops settling.
That is why the collection network is split at source:
Each stream gets its own treatment and only then joins the others. Ahead of the common treatment there is an equalisation tank, which absorbs the peaks in flow and concentration from batch rinsing. Without it, dosing is always one step behind what comes in.
An electroplating treatment line almost always follows this sequence:
The precipitant in step 3 is chosen with the analysis in front of you. Hydroxide (lime or caustic soda) is the usual choice, but there is no single pH that works for every metal: nickel needs a higher value than copper, and zinc and chromium redissolve if you overshoot. With complexing agents in the water, hydroxide falls short and you have to move to sulphides or organosulphide precipitants.
There is one approach worth ruling out early: a resin column or a selective adsorbent filter used as the main solution for a heavily loaded effluent. It does not last. The resin is exhausted, regenerations multiply and the cost per cubic metre stops making sense.
Chemical precipitation is there to take out the bulk of the load. It turns most of the dissolved metal into a solid that settles, and its performance depends on pH, on complexing agents and on how well the sludge is separated. Polishing (precipitation with chelating agents, adsorption, ion exchange) is sized for the small residue left afterwards.
Something similar happens with reverse osmosis. It allows water to be recovered for the rinses, but it needs a pretreatment that protects the membranes and it produces a concentrated reject that has to be managed. If that reject has no outlet (an evaporator, an authorised waste contractor), reuse stays on paper. What to do with spent baths and when to evaporate is covered in Surface treatment: spent baths, rinse water and metals.
Four matters rarely come up at the first meeting and then shape the project.
The sludge. Metal sludge may be classified as hazardous waste. Its collection, dewatering and waste contractor are confirmed against local regulations before the filter press is sized.
The materials. Acids, alkalis, chlorides and sulphides decide what tanks, pipes, pumps and filters are made of. They are specified for the worst possible chemistry, which is usually an accidental bath spill.
The records. Dosing, pH, residual metal and sludge leaving the site. They serve the inspector, and they let the operator see a deviation before it reaches the official analysis.
The tests. The factory test checks that the equipment works before it is shipped. It says nothing about the discharge. Acceptance takes place on site, with the real water, the finished installation and the site’s operating conditions. In the contract it is best to make them two separate milestones.
Tell us which baths you have, which metals show up in your latest analysis and whether you want to discharge or reuse. With that information we can tell you which streams to separate and which stages you need.
Only if there are no cyanide baths and no hexavalent chromium. If there are, each needs its own pretreatment before mixing: cyanide destruction takes place in alkaline conditions and chromium reduction in acidic conditions, so they cannot share a tank.
Most likely there are complexing agents. The chelating agents in some baths keep the metal dissolved at any pH. They have to be identified in the analysis, and then you either change the precipitant or break the complex before precipitating.
It depends on the price of water, on discharge charges and on what it costs to manage the reject. Technically it works if the pretreatment is good. Before deciding, the outlet for the concentrate has to be settled.
AUTHOR
WIZZUM engineering teamWe design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.
NEED HELP?
05/11/2024
Which parameter is exceeded, why and when: steps to correct an industrial discharge and technologies by pollutant, from physico-chemical treatment to MBR.
Read the article →
10/12/2024
Heat pump, mechanical vapor recompression (MVR) or multiple-effect thermal evaporator: energy use, capacities and criteria for choosing a vacuum evaporator.
Read the article →
14/04/2026
When a softener is enough for boiler and process water, when demineralization is needed and how ion exchange resins are combined with reverse osmosis.
Read the article →
OFFICE
Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com
© 2026 Wizzum. All rights reserved.