Home / Blog / Industrial wastewater

INDUSTRIAL WASTEWATER

How to reduce sludge volume and what it costs to manage

Sludge with 4% dry solids is almost all water. How to dewater it in a filter press to 30–40% and what that means for volume and disposal costs.

W
WIZZUM engineering teamPublished on 17/06/2025 · 6 min read

CONTENTS

IN SHORT

  • Sludge from a clarifier or a flotation unit usually has 2–6% dry solids. When you pay for its disposal, you are mainly paying to transport water.
  • Dewatering it from 4% to 35% dry solids reduces the mass to be removed by almost 89%.
  • The filter press produces the driest cake (30–40%) with moderate energy use.

Every treatment plant, biological or physico-chemical, produces sludge. And sludge from a clarifier or a flotation unit is, above all, water: it usually has between 2 and 6% dry solids. When you pay a waste manager to take it away, you are paying to transport water. Dewatering is one of the investments with the clearest payback in a treatment plant.

The calculation worth doing

Let’s say a plant produces 100 tonnes of sludge a month with 4% dry solids. That is 4 tonnes of solids and 96 tonnes of water.

After dewatering to 35% dry solids, those 4 tonnes of solids fit into about 11.4 tonnes of cake. The mass to be removed falls by almost 89%. If the waste manager charges per tonne, the bill falls by a similar proportion, and there are also fewer truck trips and less storage space is needed.

The exact result depends on the sludge and the rates, but the order of magnitude explains why dewatering pays for itself quickly at many plants.

Dewatering methods

TechnologyTypical cake dry solids
Filter press30–40 %
Centrifuge20–25 %
Belt filter15–25 %
Screw press18–25 %
Thermal drying70–90%, with much higher energy use

At most industrial treatment plants, the filter press produces the driest cake with moderate energy use. The screw press is quiet, uses very little energy and is often chosen for small amounts of sludge.

How the filter press works

A hydraulic cylinder closes a pack of plates covered with filter cloths. A pump drives the sludge into the chambers formed by the plates. The water passes through the cloths and leaves as filtrate, while the solids stay behind and compact as the pressure rises. At the end of the cycle, the filter opens and the cakes drop into a hopper or a container.

123

1 Filter plates 2 Hydraulic cylinder 3 Filter cake

The sludge is pumped into the plate pack, the filtrate passes through the cloths and the cakes drop into the container.
  • Cake dry solids: 30–40%; membrane squeezing adds 3–8%
  • Plates from 250 to 1,500 mm and pressures from 6 to 16 bar
  • Full cycle of 60 to 120 minutes
  • Feed sludge: 3–6% dry solids, well coagulated
  • Energy use: 5 to 15 kWh per tonne of dry solids

What determines whether the filter press works well

Sludge conditioning. Unflocculated sludge clogs the cloths and produces wet cakes. Polyelectrolyte is dosed, usually 2 to 10 kg per tonne of dry solids, and with some sludges, coagulant or lime. The dose is set by testing: overdosing also makes filtration worse.

Prior thickening. Sludge that is too dilute lengthens filling. If it leaves the clarifier below 3%, it is worth thickening it first.

The right pressure. Each sludge has its optimum pressure: around 6–8 bar for biological sludge and 7–10 bar for physico-chemical and industrial sludge. More pressure does not dry it further and wears the cloths.

Cloths in good condition. They are washed with water after the cycles that require it and replaced every six months to two years, depending on the sludge. Slower filtration, a wetter cake or higher pressure at the same flow are signs they need checking.

Manual or automatic

The smallest filter presses are opened and discharged by hand. Automatic ones shift the plates with chains or a carriage and shake them so the cakes drop. Automation costs more, but at plants with several cycles a day it greatly reduces the operator’s workload.

Sizing data

  • Sludge quantity: flow rate and solids concentration
  • Type of sludge: biological, physico-chemical, oily, metal-bearing
  • Hours per day available for dewatering
  • Target dry solids
  • A filtration test with a sludge sample, which shows the cake density and the actual cycle time

With this data, the cake volume per cycle is calculated and, from it, the size and number of plates.

The filtrate

The water leaving the filter press is usually of good quality and goes back to the head of the treatment plant. Sometimes it can be used as process water.

Before dewatering: thickening

Clarifier sludge may have only 0.5–1% solids. Thickening it first, by gravity to 3–5% or in a flotation unit to 5–6%, greatly reduces the dewatering equipment and shortens the filter press cycles.

For reference: one cubic meter of sludge with 1% dry solids, dewatered to 25%, gives about 0.04 m³ of cake; the remaining 0.96 m³ is filtrate that goes back to the head of the treatment plant.

Frequently asked questions

What dry solids content does a filter press achieve?+

Usually 30–40%, and with membrane squeezing, 3 to 8 percentage points more.

How much polyelectrolyte is needed to condition the sludge?+

Usually 2 to 10 kg per tonne of dry solids. The exact dose is set by testing a sludge sample.

Filter press or centrifuge?+

The filter press produces a drier cake (30–40% versus 20–25%) with lower energy use; the centrifuge works continuously and takes up less space.

W

AUTHOR

WIZZUM engineering team

We design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.

NEED HELP?

Are you paying to dispose of sludge that is almost all water?

  • Comparative technical analyses
  • Design and delivery of turnkey installations
  • Environmental benchmarking and BAT analysis

Environmental engineering for industry.
Industrial wastewater, emissions and odors.

OFFICE

Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com

© 2026 Wizzum. All rights reserved.