Sludge with 4% dry solids is almost all water. How to dewater it in a filter press to 30–40% and what that means for volume and disposal costs.
CONTENTS
IN SHORT
Every treatment plant, biological or physico-chemical, produces sludge. And sludge from a clarifier or a flotation unit is, above all, water: it usually has between 2 and 6% dry solids. When you pay a waste manager to take it away, you are paying to transport water. Dewatering is one of the investments with the clearest payback in a treatment plant.
Let’s say a plant produces 100 tonnes of sludge a month with 4% dry solids. That is 4 tonnes of solids and 96 tonnes of water.
After dewatering to 35% dry solids, those 4 tonnes of solids fit into about 11.4 tonnes of cake. The mass to be removed falls by almost 89%. If the waste manager charges per tonne, the bill falls by a similar proportion, and there are also fewer truck trips and less storage space is needed.
The exact result depends on the sludge and the rates, but the order of magnitude explains why dewatering pays for itself quickly at many plants.
| Technology | Typical cake dry solids |
|---|---|
| Filter press | 30–40 % |
| Centrifuge | 20–25 % |
| Belt filter | 15–25 % |
| Screw press | 18–25 % |
| Thermal drying | 70–90%, with much higher energy use |
At most industrial treatment plants, the filter press produces the driest cake with moderate energy use. The screw press is quiet, uses very little energy and is often chosen for small amounts of sludge.
A hydraulic cylinder closes a pack of plates covered with filter cloths. A pump drives the sludge into the chambers formed by the plates. The water passes through the cloths and leaves as filtrate, while the solids stay behind and compact as the pressure rises. At the end of the cycle, the filter opens and the cakes drop into a hopper or a container.
1 Filter plates 2 Hydraulic cylinder 3 Filter cake
Sludge conditioning. Unflocculated sludge clogs the cloths and produces wet cakes. Polyelectrolyte is dosed, usually 2 to 10 kg per tonne of dry solids, and with some sludges, coagulant or lime. The dose is set by testing: overdosing also makes filtration worse.
Prior thickening. Sludge that is too dilute lengthens filling. If it leaves the clarifier below 3%, it is worth thickening it first.
The right pressure. Each sludge has its optimum pressure: around 6–8 bar for biological sludge and 7–10 bar for physico-chemical and industrial sludge. More pressure does not dry it further and wears the cloths.
Cloths in good condition. They are washed with water after the cycles that require it and replaced every six months to two years, depending on the sludge. Slower filtration, a wetter cake or higher pressure at the same flow are signs they need checking.
The smallest filter presses are opened and discharged by hand. Automatic ones shift the plates with chains or a carriage and shake them so the cakes drop. Automation costs more, but at plants with several cycles a day it greatly reduces the operator’s workload.
With this data, the cake volume per cycle is calculated and, from it, the size and number of plates.
The water leaving the filter press is usually of good quality and goes back to the head of the treatment plant. Sometimes it can be used as process water.
Clarifier sludge may have only 0.5–1% solids. Thickening it first, by gravity to 3–5% or in a flotation unit to 5–6%, greatly reduces the dewatering equipment and shortens the filter press cycles.
For reference: one cubic meter of sludge with 1% dry solids, dewatered to 25%, gives about 0.04 m³ of cake; the remaining 0.96 m³ is filtrate that goes back to the head of the treatment plant.
Usually 30–40%, and with membrane squeezing, 3 to 8 percentage points more.
Usually 2 to 10 kg per tonne of dry solids. The exact dose is set by testing a sludge sample.
The filter press produces a drier cake (30–40% versus 20–25%) with lower energy use; the centrifuge works continuously and takes up less space.
AUTHOR
WIZZUM engineering teamWe design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.
NEED HELP?
05/11/2024
Which parameter is exceeded, why and when: steps to correct an industrial discharge and technologies by pollutant, from physico-chemical treatment to MBR.
Read the article →
05/12/2023
Water treatment as part of sustainable chemical production.
Read the article →
14/03/2023
Technologies that are changing wastewater treatment in response to stricter regulations and sustainability targets.
Read the article →
OFFICE
Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com
© 2026 Wizzum. All rights reserved.