Home / Blog / Industrial wastewater

INDUSTRIAL WASTEWATER

Surface treatment: spent baths, rinse water and metals

How to treat wastewater from galvanizing, chrome plating, anodizing or phosphating: stream segregation, metal precipitation, resins for rinses and evaporation of baths.

W
WIZZUM engineering teamPublished on 19/05/2026 · 6 min read

CONTENTS

IN SHORT

  • Spent baths (low volume, high concentration) and rinse water (high volume, low concentration) are treated separately.
  • Rinse water can be precipitated chemically or recirculated in a closed loop with ion exchange resins.
  • Evaporating spent baths often pays off: the distillate goes back to the rinses and the concentrate takes up little space.

Galvanizing, chrome plating, nickel plating, anodizing, phosphating and painting plants produce two very different types of wastewater: spent baths, with low volume and high concentration, and rinse water, with high volume and low concentration. Treating them together is the most common mistake and the most expensive one. The first step is to separate them.

Stream segregation

The best approach is to treat each stream separately:

  • Concentrated degreasing, pickling or electrolytic baths.
  • Rinse water with a low metal concentration.
  • Streams with hexavalent chromium, which need prior reduction.
  • Streams with cyanides, which need prior oxidation.

If they are mixed, the whole flow has to be treated as if it were the worst one, and some mixtures, such as cyanides with acids, are dangerous.

Rinse water: precipitate or recover

Physico-chemical treatment

This is the classic solution. The pH is adjusted so that the metals precipitate as hydroxides, coagulation and flocculation follow, and the sludge is separated in a clarifier or a flotation unit. The metal-bearing sludge is dewatered in a filter press. More details in the physico-chemical treatment datasheet.

Bear in mind that each metal precipitates best at a different pH and that complexing agents in some baths make precipitation harder. Laboratory tests with the actual water are essential. We explain chromium reduction and cyanide oxidation in the article on discharges that do not meet the limits.

Ion exchange

Rinse water contains little salt. An ion exchange resin line can retain the metals and return good-quality water to the rinses in a closed loop. Selective or chelating resins capture specific metals even when other salts are present. During regeneration, the metals come out concentrated and can be recovered or treated in a small volume.

Spent baths: evaporate

Spent baths carry such a heavy load that, if they are sent to physico-chemical treatment, they upset the treatment plant and produce a lot of sludge. Handing them over to a waste manager is expensive. The alternative is vacuum evaporation: it separates the water as distillate, which can be used for rinsing, and leaves a low-volume concentrate.

In some cases, such as chrome or nickel baths, evaporation even makes it possible to return the concentrate to the bath, that is, to recover product.

  • Heat pump evaporators from 250 l/day, suitable for small amounts of bath
  • Evaporation temperature of 35–50 °C, which does not alter the products
  • Corrosion-resistant materials: super duplex steel or titanium where chlorides and fluorides are present
  • Distillate reusable in the rinses

Toward zero liquid discharge

By combining these three elements, many surface treatment plants get close to zero liquid discharge: the resins close the rinse loop, evaporation takes the baths and regenerants, and crystallization produces a solid residue if needed. The water goes back to the process and only a concentrated residue leaves the plant.

Air emissions

Hot and electrolytic baths give off mists and gases: acids from pickling, chromic acid mists, alkaline vapors. They are captured with lateral extraction on the tanks and treated in scrubbers with the right solution: alkaline for acids, and with effective mist eliminators for mists.

Where to start

  1. Bath inventory: composition, volume and renewal frequency.
  2. Measurement of the flow rate and quality of each rinse water.
  3. Analysis of metals, cyanides, hexavalent chromium, conductivity and pH.
  4. A decision for each stream: what is recirculated, what is evaporated and what goes to physico-chemical treatment.

With this data, the treatment plant usually turns out smaller, uses fewer chemicals and produces less sludge than one that treats everything together.

Example of a complete line

In an electroplating shop with a flow rate of 5 m³/h, COD of 1,500 mg/l, chromium, nickel and zinc and a low pH, a line made up of neutralization, electrocoagulation with iron plates, a lamella clarifier, a sand filter, two-stage reverse osmosis, an evaporator and a crystallizer can remove more than 95% of the metals, recover 85% of the water as permeate and reach zero liquid discharge.

123

1 Electrodes 2 Rectifier 3 Clarifier

Reactor with electrode plates powered by a rectifier; the flocs that form are separated in the clarifier.

Electrocoagulation is an alternative to chemical coagulants: iron or aluminum electrodes dissolve under the current and form the coagulant directly in the water. It works well with emulsified oils, metals and dyes, uses 0.5–2.5 kWh/m³ depending on conductivity and produces less sludge. The electrodes wear and are replaced every 3–12 months. More information in the electrocoagulation and electro-oxidation datasheet.

Frequently asked questions

Why not treat baths and rinses together?+

Because concentrated baths upset the treatment plant and force it to be sized for the worst stream. Treating them separately is cheaper and more reliable.

Can rinse water be recirculated?+

Yes. Ion exchange resins retain the metals and return good-quality water to the rinses in a closed loop.

What is done with spent baths?+

Evaporating them in a vacuum evaporator often pays off: the distillate goes back to the rinses and the concentrate takes up little space or goes back to the bath.

W

AUTHOR

WIZZUM engineering team

We design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.

NEED HELP?

Do you have a surface treatment line or an electroplating shop?

  • Comparative technical analyses
  • Design and delivery of turnkey installations
  • Environmental benchmarking and BAT analysis

Environmental engineering for industry.
Industrial wastewater, emissions and odors.

OFFICE

Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com