Knowing which parameter is exceeded, why and when is half the solution. Steps to correct an industrial discharge and technologies by type of pollutant.
CONTENTS
IN SHORT
An analysis above the limit, a notice from the water utility or a discharge penalty usually arrive with some urgency. It is tempting to buy the first unit you are offered. It is better to answer three questions first: which parameter is exceeded, why and when. With those answers, the solution is usually smaller and cheaper than it seems.
The discharge permit or the sewer discharge contract includes many parameters, but breaches tend to concentrate on a few. Each one points to a different type of treatment:
| Parameter exceeded | Usual origin | Treatment to consider |
|---|---|---|
| pH | Acid or alkaline baths, cleaning | Neutralization |
| Total suspended solids | Rinses, processes with fine particles | Coagulation, flocculation and settling, or DAF |
| Oils and fats | Food industry, machining, workshops | Dissolved air flotation (DAF) |
| COD and BOD₅ | Dissolved organic matter | Biological treatment or MBR |
| Metals (Cr, Ni, Cu, Zn…) | Surface treatment | Chemical precipitation and separation |
| Conductivity and salts | Regenerations, brines, osmosis concentrate | Membranes or evaporation |
| Color, toxic and poorly biodegradable compounds | Chemicals, textiles, pharmaceuticals | Advanced oxidation or adsorption |
Wastewater is rarely out of spec all the time. Breaches usually occur at specific moments: when a spent bath is emptied, during weekend cleaning, at a product changeover. That is why it is worth:
This is the basis of most industrial treatment plants. The pH is adjusted, a coagulant is added to destabilize the fine particles (0.001 to 1 mm), and a flocculant binds them into flocs. If there are metals, chemical precipitation turns them into solids. Those solids then have to be separated from the water. More details in the physico-chemical treatment datasheet.
1 Coagulation 2 Flocculation 3 Lamella clarifier 4 Reagent dosing
When the water contains oils, fats or light flocs, flotation separates them better than settling. Water saturated with air under pressure is introduced, and the microbubbles lift the particles to the surface, where a scraper removes them. More information in the DAF flotation datasheet.
If dissolved organic matter is what exceeds the limit, physico-chemical treatment is not enough and biological treatment or an MBR is needed. If it is salts, no conventional method removes them: you have to turn to reverse osmosis or vacuum evaporation. With very difficult water, evaporation even makes it possible to stop discharging altogether and reuse the water.
With a representative sample, coagulation and flocculation tests (jar tests) can be carried out to check which reagents work, at what dose and what water quality they give. It is cheap and avoids surprises at commissioning.
Every physico-chemical treatment produces sludge. Its quantity and management are part of the cost. A filter press can reduce it to a cake with 30–40% dry solids, which greatly lowers transport and disposal costs.
To compare quotes from different suppliers, they should all answer the same questions:
A quote that does not say what water it was designed for gives no way of knowing whether the installation will meet the limits.
| Parameter | Indicative value |
|---|---|
| Equalization tank | At least 4–6 h of inlet flow |
| Rapid mixing (coagulation) | 800–1,200 s⁻¹ for 30–60 s |
| Slow mixing (flocculation) | 20–80 s⁻¹ for 15–30 min |
| Ferric chloride dose | 50–200 mg/l |
| Polyelectrolyte dose | 1–5 mg/l |
| Settling velocity | 0.5–1 m/h; up to 3 m/h in a lamella clarifier |
| DAF hydraulic loading | 5–15 m³/m²·h |
| Sludge quantity | 1–2% of the treated water volume, around 3–6 kg/m³ |
| Energy consumption | Coagulation, 0.05–0.15 kWh/m³; DAF, 0.2–0.6 kWh/m³ |
Two pollutants need their own stage before physico-chemical treatment. Hexavalent chromium is reduced to trivalent chromium at pH 2–3 with ferrous sulfate or metabisulfite, at a redox potential of around +250 mV; the pH is then raised to 8–9 and the chromium precipitated. Cyanides are oxidized to cyanates with hypochlorite at pH 10–11 and a redox potential of 600–650 mV; the high pH prevents hydrogen cyanide from being released. In both cases, the process is controlled continuously with pH and redox probes.
No. Often it is enough to separate a concentrated stream, add an equalization tank or improve reagent dosing at the existing installation.
The flotation unit lifts the pollutants to the surface with air microbubbles. It works better with oils, fats and light flocs, and takes up less space.
No. Dissolved salts are removed with reverse osmosis or vacuum evaporation.
AUTHOR
WIZZUM engineering teamWe design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.
NEED HELP?
05/12/2023
Water treatment as part of sustainable chemical production.
Read the article →
14/03/2023
Technologies that are changing wastewater treatment in response to stricter regulations and sustainability targets.
Read the article →
13/08/2024
Properties of ethylene oxide and ways to treat wastewater containing it.
Read the article →
OFFICE
Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com
© 2026 Wizzum. All rights reserved.