An RTO heated by electric heating elements instead of a burner. How it works, when it uses electricity and when it doesn’t, and what to check at the plant before choosing it.
CONTENTS
IN SHORT
A classic RTO uses a gas burner at start-up and when the VOC concentration is not enough to hold the temperature. The e-RTO does the same with electric heating elements mounted in the oxidation chamber. The towers, ceramic beds and valves are the same. The heat source changes and, with it, the unit’s own emissions.
The VOC-laden gas enters through one tower, heats up in the ceramic bed and reaches the oxidation chamber. Instead of a flame, there is a set of heating elements there that holds the operating temperature, usually around 850 °C and, depending on the design, up to 1100 °C. The VOCs are oxidized to CO₂ and water, and the clean gas gives off its heat to the bed in the second tower before leaving. The valves reverse the flow direction every cycle.
1 Electric heating elements 2 Ceramic beds 3 Power supply 4 Stack
The e-RTO’s energy use depends on the emission, just like the gas consumption of a classic RTO:
A plant whose average concentration is above that point will pay very little for heating. A plant with a very dilute emission will use energy continuously, just as it would use gas.
For plants with Scope 1 emission reduction targets or that already have their own photovoltaics, it is a simple way to remove a gas consumer.
Available electrical power. This is the key point. Start-up requires the full power of the heating elements and, with a dilute emission, continuous operation also uses a fair amount of energy. The contracted power, the transformer and the main switchboard have to be checked.
The real average concentration. The longer the e-RTO runs above the autothermal point, the less the electricity price matters. Without measuring over a full production cycle, it cannot be estimated properly.
Electricity price versus gas price. With a dilute emission, which almost always needs heat input, the cost comparison depends on the plant’s tariffs. With on-site photovoltaics, the numbers tip in favor of the e-RTO during sunny hours.
Shutdowns and start-ups. If the line stops every night, each start-up uses energy to reheat the chamber. It is worth calculating whether keeping the unit on hot standby works out better.
In some cases, the burner of an operating RTO can be replaced with a set of heating elements. It depends on the chamber design, the space and the available power. It is worth considering when the burner reaches the end of its service life or the plant has an electrification plan.
| Burner-fired RTO | e-RTO | |
|---|---|---|
| Heat source | Natural gas, LPG, biogas or hydrogen | Electric heating elements |
| NOx from heating | Yes, from combustion | No |
| CO₂ from heating | Yes | Zero with renewable electricity |
| Installation | Gas connection and gas train | High-power electrical connection |
| Removal efficiency | > 99 % | > 99 % |
| Consumption above the autothermal point | Almost zero | Zero |
Essentially it is the same unit with a different heat source. The choice depends on the energy available at the plant, its price and the company’s emission reduction targets.
Yes. In both cases efficiency exceeds 99%, because the oxidation process and the beds are the same.
When the VOC concentration is above the autothermal point. The heat then comes from the pollutants themselves and the heating elements are off.
Sometimes. It depends on the chamber design, the space for the heating elements and the power available at the plant.
AUTHOR
WIZZUM engineering teamWe design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.
NEED HELP?
16/04/2024
Flow rate, concentration, composition and operating hours decide the technology. A comparison of RTO, catalytic oxidation, zeolite and activated carbon.
Read the article →
06/06/2023
Are eco-friendly alternatives always better? A technical view without greenwashing.
Read the article →
27/02/2024
Efficiency, operating temperature, energy use and maintenance of the three most widely used technologies, and how to choose the right one for your plant.
Read the article →
OFFICE
Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com
© 2026 Wizzum. All rights reserved.