A treatment installation is designed from emission data. What to measure, for how long, and which mistakes make the unit too expensive or leave it undersized.
CONTENTS
IN SHORT
Most emission treatment installations that perform poorly have no manufacturing defect. They were designed with data that did not match the real emission: with the flow rate from the fan nameplate, with a concentration measured on a low-production day or with a composition nobody checked. A good measurement costs little compared with redoing a finished installation.
This is the data any engineering firm needs to size a VOC treatment installation and compare the options with numbers:
| Parameter | What it is for |
|---|---|
| Flow rate (Nm³/h) | Size of the unit, fan and ductwork |
| Gas temperature | Condensation, choice of materials, energy required |
| Humidity | Efficiency of activated carbon and zeolite, risk of condensation |
| Total organic carbon (TOC) | VOC load and oxidizer energy use |
| VOC composition | Compounds that destroy catalysts or form acids |
| CO and NOx | When there is combustion in the process or in the existing unit |
| Dust and aerosols | Need for prefiltration |
| Oxygen | Correction of results and process safety |
TOC is normally measured continuously with a flame ionization detector (FID) analyzer. It gives the total load of organic compounds expressed as carbon, which is what the oxidizer designer needs. Specific compounds are determined in samples analyzed in the laboratory.
A one-hour measurement is enough to check whether the source meets the limit. For design purposes it is not enough. The emission changes with the product being made, the shift, line cleaning and the time of year. It is best to measure a full production cycle and, if the products are very different, to measure each one.
We look for four things:
With these four figures, the annual energy consumption of each technology can be calculated. That is precisely what sets one option apart from another.
Before measuring, it is worth gathering what already exists:
Sizing for the fan’s nominal flow rate. Fans rarely work at their nominal point. A unit designed for a higher flow rate than the real one is more expensive to buy and to keep at temperature.
Diluting to meet the limit. Adding clean air lowers the concentration at the stack, but increases the flow to be treated. On top of that, the diluted emission usually ends up below the point at which the oxidizer runs without fuel.
Combining sources without analyzing them separately. Joining a paint booth and an oven into a single installation can make sense, but it can also mean treating a lot of air with little load. Each source has to be measured separately before deciding.
Forgetting what isn’t VOCs. Silicones, chlorinated compounds, dust or aerosols change the choice of technology or call for pretreatment stages. If nobody measures them, they show up later: as a poisoned catalyst, a blocked bed or corrosion.
When there are odor complaints, measuring VOCs is not enough. Many odorous compounds, such as H₂S, mercaptans or amines, can be detected at concentrations in the ppb range, far below the threshold of a TOC analyzer or a portable detector. Other methods are needed:
| Method | What it gives |
|---|---|
| Dynamic olfactometry (EN 13725) | Odor concentration of each source in ouE/m³; combined with the flow rate, it gives the odor emission |
| Chemical analysis of specific compounds | Sulfur compounds, amines, fatty acids or specific VOCs, with a limit of quantification below the odor threshold |
| Field inspection (EN 16841) | Whether the odor reaches the surrounding area, how often and where |
The rules for good sampling are the same as for VOCs, with a few additions:
A practical tip: if the laboratory reports “not detected”, check that the limit of quantification is below the odor threshold. If it isn’t, the compound may still be smelled even though the report says it isn’t there. We discuss the test itself further in the article on olfactometry tests.
Take a line with an extraction rate of 20,000 Nm³/h and an average VOC concentration of 1.5 g/Nm³. That is around 30 kg of VOCs per hour, enough for an RTO to run almost without fuel.
Now suppose that, to lower the concentration at the stack, an additional air inlet is opened and the flow rate rises to 40,000 Nm³/h. The VOCs are the same, 30 kg/h, but the concentration drops to 0.75 g/Nm³. The RTO has to be twice as large and needs gas continuously to hold its temperature. The emission has not changed; the cost of treating it has.
The opposite also happens. If the measurement was made on a low-production day and the real concentration is double, the unit may operate above its thermal capacity, with high-temperature trips and line stoppages. In both cases the cause is the same: a design done without knowing the emission well.
For the report to be useful to the designer, it has to go beyond the average value required in an inspection. It should include:
With the emission properly described, two or three technologies can be compared using the same data: investment, annual energy use, maintenance and footprint. Our article on how to choose a VOC treatment technology gives a first steer by flow rate and concentration, and we describe the scope of our measurements in the piece on air and gas measurements.
Usually not. A compliance measurement is short and shows whether the source meets the limit. For the design, you need a record of how the concentration changes over a full production cycle.
As long as a full production cycle. If there are several different products, it is worth measuring each one, because each gives a different emission.
The samples are analyzed by an independent accredited laboratory. We plan the measurements, supervise the sampling and interpret the results with the design in mind.
AUTHOR
WIZZUM engineering teamWe design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.
NEED HELP?
16/04/2024
Flow rate, concentration, composition and operating hours decide the technology. A comparison of RTO, catalytic oxidation, zeolite and activated carbon.
Read the article →
19/09/2023
Air and gas measurements help you control emissions, improve air quality and comply with regulations.
Read the article →
03/02/2026
Odor is not a subjective complaint but a measurable parameter. Tests show how efficiently an odor control installation works.
Read the article →
OFFICE
Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com
© 2026 Wizzum. All rights reserved.