Slaughterhouses, dairies, canneries and beverage makers: how fats are separated, how high COD is brought down and which treatment sequence usually works.
CONTENTS
IN SHORT
Food industry wastewater has a very recognizable profile: lots of organic matter, fats and oils, suspended solids and flow rates that change with shifts and cleaning. Almost all of it is biodegradable, and that is the good news. The bad news is that the load can be so high that, untreated, the discharge breaches the contract conditions or the discharge charges shoot up.
In all of them, CIP cleaning causes pH and detergent peaks that have to be dampened.
The screen removes coarse solids, and the equalization tank evens out flow, pH and load over the day. It is cheap and protects everything downstream.
Fats and fine solids float better than they settle. In the DAF unit, the water is mixed with air microbubbles that lift fats and flocs to the surface, where a scraper removes them. With coagulant and flocculant, part of the COD bound to suspended solids is also removed.
1 Flotation chamber 2 Scraper 3 Saturator
Dissolved COD (sugars, lactose, soluble proteins) is removed by microorganisms. There are two routes:
With COD of several thousand mg/l and enough flow, the anaerobic stage gives the best economic result. With moderate loads, an aerobic-only system is simpler. We compare aerobic systems in the article “MBR or conventional biological treatment”.
If the water has to go back to cleaning or auxiliary uses, an MBR or ultrafiltration with reverse osmosis provides good-quality water. In the food industry, the permitted uses of reclaimed water are limited by health regulations and have to be studied case by case.
Fats reaching the biological stage. They form foam, float in the clarifier and foul MBR membranes. A properly sized DAF is the best protection.
Cleaning peaks. Caustic soda, acids and disinfectants can inhibit the bacteria. Equalization and neutralization are essential.
Nutrients. Some wastewaters, such as those from beverages, have high COD and little nitrogen and phosphorus, and these have to be added for the biological stage.
Odors. Water with a high organic load ferments quickly. Covered tanks and air extraction may be needed.
Sludge. The DAF and the biological stage produce a fair amount of sludge. Dewatering it in a filter press greatly reduces disposal costs.
The first step is to characterize the water over several days, with flow measurements and analyses at different times, including during cleaning: total and soluble COD, BOD₅, suspended solids, oils and fats, nitrogen, phosphorus, pH and temperature. With that data you can decide whether a DAF is enough to comply, whether a biological stage is needed and whether the anaerobic stage will pay for itself with the biogas.
From around 3,000 mg/l of COD, an anaerobic stage usually pays off. There are two common solutions:
| UASB | EGSB | |
|---|---|---|
| Organic load | 5–10 kg COD/m³·d | 10–25 kg COD/m³·d |
| Retention time | 6–12 h | 2–6 h |
| Upflow velocity | 0.5–1 m/h | 3–10 m/h |
| Suitable water | Medium and high load; tolerates some solids | High load and few solids |
The EGSB takes up less space and accepts a higher load, but needs water with few suspended solids, which makes the upstream flotation more important.
At a cheese factory with a flow rate of 20 m³/h and COD of 6,000 mg/l, a line with a plate separator, DAF with coagulant and polymer, MBR and UV disinfection can reduce COD by more than 96%, to around 150 mg/l, with BOD₅ below 10 mg/l and suspended solids below 5 mg/l. At a snack factory, with starch and oil, a line of DAF, MBR, reverse osmosis and partial evaporation makes it possible to reuse around 75% of the water and send the oil and starch to biogas production.
Sometimes yes, if the problem is mainly fats and suspended solids. If dissolved COD is what exceeds the limit, a biological stage is needed.
Usually from around 3,000 mg/l of COD and with enough flow. It reduces energy use and produces biogas.
Yes, for cleaning or auxiliary uses, but the permitted uses are limited by health regulations and have to be set case by case.
AUTHOR
WIZZUM engineering teamWe design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.
NEED HELP?
14/10/2025
How a membrane bioreactor (MBR) differs from activated sludge and MBBR: water quality, space, energy use and maintenance. When each option pays off.
Read the article →
05/11/2024
Which parameter is exceeded, why and when: steps to correct an industrial discharge and technologies by pollutant, from physico-chemical treatment to MBR.
Read the article →
17/06/2025
Sludge with 4% dry solids is almost all water. How to dewater it in a filter press to 30–40% dry solids and how much you can save on disposal.
Read the article →
OFFICE
Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com
© 2026 Wizzum. All rights reserved.