Paint shops: how to treat VOCs from booths and drying ovens

Booths with high air flow and low concentration, drying ovens with low flow and a higher load. How VOCs from a paint line are treated.

W
WIZZUM engineering teamPublished on 09/07/2024 · 5 min read

CONTENTS

IN SHORT

  • A paint line has at least two different emissions: one from the booths and one from the drying ovens. Treating them the same way usually ends up being expensive.
  • In the booths, the usual approach is to concentrate the VOCs first in a zeolite concentrator and then oxidize them.
  • Oxidizer heat returned to the drying oven often decides the payback of the whole installation.

A paint line has at least two very different types of emission: from the booths, where the paint is applied, and from the dryers or ovens, where the solvent left on the part evaporates. Treating them the same way usually ends up being expensive. First they have to be separated and each one measured on its own.

Two emissions with opposite profiles

Paint booths. A lot of air passes through them, protecting the operator and carrying away the paint mist. The flow rate is large, often several tens of thousands of Nm³/h, and the VOC concentration is low. The air also carries paint particles (overspray) that have to be captured before any treatment.

Dryers and ovens. They work with much less air and at elevated temperature. A large part of the solvent evaporates in them, so the concentration is considerably higher. Per kilogram of VOCs removed, this is the easiest source to treat.

The booth: reduce the flow rate first

Heating tens of thousands of cubic meters per hour to 800 °C just to remove a low concentration is expensive. That is why, in booths, the usual approach is to concentrate the VOCs first.

The zeolite concentrator passes the air through a rotor that retains the VOCs. A small sector of the rotor is heated with a reduced flow of air, which carries away the concentrated VOCs. The result is a flow up to 16 times smaller, with a much higher concentration, which goes to a small oxidizer.

1234

1 Prefilter 2 Zeolite rotor 3 Oxidizer 4 Stack

The rotor retains the VOCs from the large booth air flow and releases them into a much smaller flow that goes to the oxidizer.
  • Usual inlet concentration: below 1 g/Nm³
  • Reduction of the flow to be treated: up to 16 times
  • Heat from the rotor cooling zone is used for desorption
  • Particles must be filtered out ahead of the rotor

Prefiltration is essential. Paint particles block the rotor and any ceramic or catalyst bed. The usual setup combines several stages of dry filters with a fine filter ahead of the concentrator.

There is also a way to reduce the flow without touching production: recirculating part of the booth air, if the design and operator safety allow it. Every cubic meter that does not reach the stack is a cubic meter that does not have to be treated.

The drying oven: oxidation and heat recovery

In drying ovens, the concentration is usually enough to send the gas directly to an oxidizer. The most common options are:

  • RTO, when the flow rate is medium or large or it is going to be combined with the concentrated gas from the booths.
  • Recuperative oxidation, when the flow rate is small and the concentration high. The surplus heat can go back to the oven as hot air or thermal oil.
  • Catalytic oxidation, when the composition is controlled and there are no silicones or other compounds that damage the catalyst.

Returning heat to the oven is precisely what often decides the payback: the oven uses less gas and the oxidizer stops being just a cost.

One unit or two?

Many plants end up with a single oxidizer, which receives the gas from the drying oven and the concentrated gas from the booths. It is a good solution if the flow rates and schedules fit together. If the booths work different shifts from the oven or the line stops often, it may be better to treat each source separately.

What to measure on a paint line

  • The flow rate of each booth and each drying oven, separately
  • The VOC concentration at each source over a full cycle
  • The particles in the booth air
  • The presence of silicones in paints, release agents and additives
  • The annual consumption of paints, varnishes and cleaning solvents
  • The operating hours of each line

With this data you can decide whether to concentrate, which oxidizer to send each stream to and how much heat can be returned to the process. We discuss measurements further in the article “Measure first, then design”.

Common mistakes

Treating booth air without good filtration. Overspray reaches the zeolite rotor or the ceramic beds and leads to unplanned cleaning and replacement.

Forgetting cleaning solvents. Cleaning guns, circuits and booths produces concentration peaks that are not visible when measuring during normal production.

Not taking product changes into account. Switching to high-solids or waterborne paints reduces VOC emissions, but not always in the same proportion in the booth and in the oven. Before investing, it is worth knowing which products will be used in the coming years.

Forgetting about silicones. Some additives and release agents contain silicones, which destroy catalysts and, over time, RTO beds too. This has to be checked in the safety data sheets.

Frequently asked questions

Can booth air be sent directly to an RTO?+

It can, but with a high flow rate and low concentration the RTO will be large and will burn fuel continuously. It is usually cheaper to concentrate the VOCs first in a zeolite concentrator.

Why is filtration ahead of the concentrator so important?+

Because paint particles block the rotor channels and the oxidizer beds. Without good filtration, cleaning and replacement costs shoot up.

Does switching to waterborne paints solve the emissions problem?+

It reduces them, but not always enough, nor equally in the booth and in the oven. It is best to base the decision on the installation on product plans several years ahead.

W

AUTHOR

WIZZUM engineering team

We design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.

NEED HELP?

Do you have a paint line with VOC emissions?

  • Comparative technical analyses
  • Design and delivery of turnkey installations
  • Environmental benchmarking and BAT analysis

Environmental engineering for industry.
Industrial wastewater, emissions and odors.