Home / Blog / Air and VOCs

AIR AND VOCs

Acid gases and ammonia: how to choose the scrubber reagent

Water, caustic soda, sulfuric acid, hypochlorite or bisulfite: which scrubbing solution removes each gas, how it is controlled and when several stages are needed.

W
WIZZUM engineering teamPublished on 20/01/2026 · 5 min read

CONTENTS

IN SHORT

  • In many cases the column can be almost the same. What determines efficiency is the scrubbing liquid.
  • Acid gases are neutralized with an alkaline solution, and alkaline gases with an acid one. Other compounds are oxidized or reduced.
  • With gas mixtures, several columns are placed in series, each with its own solution.

A chemical scrubber is a column in which the gas is scrubbed countercurrent with a solution that captures the pollutants. In many cases the column itself can be almost the same. What changes is the scrubbing liquid, and the choice of liquid decides whether the unit reaches 99% efficiency or falls short.

The basic rule: the opposite reagent

Acid gases are neutralized with an alkaline solution, and alkaline gases with an acid solution. Compounds that do not react this way are oxidized or reduced. Hence the table:

Gas to be removedScrubbing solution
HCl, HF, HBr, SO₂, H₂SO₄, HNO₃, H₂S, mercaptansAlkaline: sodium hydroxide (NaOH)
Ammonia, amines, ethylene oxideAcid: sulfuric acid (H₂SO₄)
H₂S and organic sulfides, odorsOxidizing: sodium hypochlorite
Chlorine, bromine and other halogensReducing: sodium bisulfite
Highly soluble gases (HCl, NH₃, alcohols, acetone)Water, no reagents
1234

1 Mist eliminator 2 Packing 3 Tank with recirculation pump 4 Reagent dosing

Packed column scrubbed countercurrent, with recirculation and reagent dosing.

Water scrubbing

Some gases dissolve so well that water is enough: HCl, ammonia, alcohols, acetone. It is the simplest option, with no reagent storage. The water scrubber works once-through, with a continuous supply of clean water, or with a double loop. The limitation is that the bleed water has to be reused or treated, and at high concentrations water consumption shoots up.

It is widely used on tank farm vents, where the emission rises during filling.

Alkaline scrubbing

Sodium hydroxide is the most common reagent for acid gases. With pH control and solution renewal governed by conductivity, the alkaline scrubber exceeds 99% efficiency with HCl, HF and H₂S. Two things need to be considered: caustic soda also absorbs CO₂ from the air, which increases its consumption, and salts may precipitate at high salinity or low temperature. It is best to soften the make-up water.

Acid scrubbing

Sulfuric acid is the most common reagent for ammonia and amines, because of its low cost and low vapor pressure. Under optimal conditions, the acid scrubber exceeds 99% efficiency. In multi-stage systems it also removes epoxides such as ethylene oxide, with efficiencies of up to 99.9999%. The bleed is a saline solution; in the case of ammonia, ammonium sulfate. We discuss ethylene oxide further in the article on sterilization gases.

Oxidizing and reducing scrubbing

Sodium hypochlorite oxidizes H₂S and organic sulfur compounds (see the oxidizing scrubber). Sodium bisulfite reduces chlorine and bromine (reducing scrubber). In both cases, dosing is controlled by redox potential and pH.

When several stages are needed

Many emissions contain both acid and alkaline gases, or gases that react with each other. In that case, columns are placed in series, each with its own solution:

  • Ammonia + H₂S (composting plants, wastewater treatment plants): acid first, then alkaline or oxidizing. The ammonia has to be removed before it reaches the hypochlorite, so that chloramines do not form.
  • HCl + chlorine (chemical processes): alkaline first, then reducing.
  • Acid gases + dust: a Venturi scrubber for the dust followed by a packed column for the gases.

Vertical or horizontal column

Vertical, countercurrent: small footprint, but tall. This is the most common version.

Horizontal, crossflow: lower, with better weight distribution and longer contact time. It is useful in buildings with limited headroom and on roofs.

Materials

Plastics (PP, PVDF) withstand acids and caustic soda very well, but limit the temperature to around 80–90 °C. Hotter gases have to be cooled first, or stainless steel used. With fluorides and some oxidants, the compatibility of each material has to be checked.

What to know before the project

  • Which gases the emission contains and at what concentration, including peaks
  • The gas flow rate and temperature
  • Whether there are particles or aerosols
  • Where the bleed will go: to the plant’s own wastewater treatment, to a waste manager or to reuse
  • Which emission limits have to be met

With this data, the reagent, the number of stages and the size of each column are chosen.

Frequently asked questions

Which reagent is used to remove ammonia?+

Usually sulfuric acid. It is cheap, has a low vapor pressure and efficiency exceeds 99%.

What are HCl and HF removed with?+

With a sodium hydroxide solution in an alkaline scrubber. HCl also dissolves very well in plain water.

Why shouldn't ammonia be combined with hypochlorite?+

Because chloramines form, which smell and are irritating. That is why ammonia is removed in a first acid stage.

W

AUTHOR

WIZZUM engineering team

We design and commission wastewater and gas treatment installations for industry, from benchmarking and FEED engineering to start-up.

NEED HELP?

Are you choosing a scrubber for acid gases or ammonia?

  • Comparative technical analyses
  • Design and delivery of turnkey installations
  • Environmental benchmarking and BAT analysis

Environmental engineering for industry.
Industrial wastewater, emissions and odors.

OFFICE

Avda. Cabrera, 36
08302 Mataró (Barcelona), Spain
info@wizzum.com

© 2026 Wizzum. All rights reserved.